Product Overview
The ER17335 is a 2/3A-size lithium thionyl chloride battery — Li-SOCl2 for short — rated 3.6 V nominal with 2200 mAh nominal capacity, built in a bobbin construction and sealed into a metal can that weighs 19 g. It is a primary cell, so it delivers its energy once, slowly and steadily, across a service life measured in years rather than cycles.
That makes it a fit for instruments that are sealed, installed and left alone: flow meters and utility meters, remote monitoring nodes, and the memory-hold-up circuits that keep clocks and registers alive when main power drops. The load is small and steady, broken only by short bursts when the device transmits or actuates a valve.
Most designs use a single cell per instrument, either replacing an alkaline pack or specifying it from the start as the only power source. Because it is a primary lithium battery, the circuit needs no charging stage, no charge management and no cycling routine — and equally, nothing in the instrument may feed voltage back into the cell.
If the design does have to be recharged from mains, solar or a docking station, a rechargeable lithium battery is the correct chemistry and the charge control has to be designed for it. The 2/3A cell here is a one-way energy reserve.
Chemistry & Performance
- Flat voltage plateau. A lithium thionyl chloride battery holds close to its nominal voltage through most of the discharge, so readings, timestamps and transmissions stay stable instead of sagging gradually the way an alkaline curve does.
- Bobbin construction. The bobbin electrode is built for small continuous loads — the way a meter actually draws power — and it is the reason this chemistry reaches such a high energy density.
- Energy density above 650 Wh/kg. That is roughly three to ten times what other lithium series deliver for the same weight, which is how a cell this small can carry a metering node for years.
- Pulse capability. Continuous current is deliberately modest, but the cell will deliver short pulses for a radio transmission or a valve action; size the peak load against the pulse rating, not the continuous one.
- Hermetic glass-to-metal sealing. The seal is what decides whether a cell survives years in a damp cabinet; glass-to-metal construction keeps the electrolyte in and moisture out for the whole service life.
- Temperature range from -60 °C to +85 °C. That covers cold meter pits, unheated plant rooms and sun-exposed cabinets. Check that the display, gaskets and plastics around the cell are rated for the same window.
- One long discharge, not thousands of cycles. A LiFePO4 battery is built for repeated charging and discharging; this cell is built to be fitted once. If the instrument is recharged, the chemistry has to be a rechargeable one.
Cell Format & Fit
- Measure the compartment, not just the cell you are replacing. The can's maximum diameter and height are listed under Specifications, and the holder, spring and lid all have to clear those figures with the cell seated.
- Confirm the terminal style the holder expects — button top, flat top, tab or wire lead — and state it on the order so the right variant is quoted.
- Check the height budget. The listed height is a maximum, so add the thickness of any foam pad, gasket or PCB that sits above the cell.
- Match the circuit to the discharge window. For this Li-SOCl2 battery, nominal voltage is 3.6 V and the cut-off is 2.0 V, so set the low-battery warning comfortably above 2.0 V to leave time for a service visit.
- Watch polarity during assembly. Fit the cell the right way round and mark the holder clearly; a reversed primary cell can damage the circuit long before anyone notices the fault.
- Build one instrument before the production run. Fit a sample into the real housing, run a transmit burst at the cold end of the operating range, and confirm the voltage margin holds.
Applications
Utility and flow metering is the core job. Water, gas, heat and electricity meters — including the flow meters this cell is most often specified for — use it to run the metering electronics, hold the register and drive valve or communication bursts between service visits.
Memory and clock backup is the second large family: real-time clock hold-up, data backup supplies and parameter memory in instruments that lose mains power. Those loads sit in the microamp range for most of the year, which is exactly where a bobbin cell is most efficient.
Safety and monitoring devices rely on the same chemistry whenever a unit has to be self-contained and maintenance-free for years — smoke alarms, temperature monitors, anti-theft alarms and tyre-pressure sensors among them.
Remote, marine and field telemetry covers GPS trackers, marine telemetry and marine electronics, sea lifesaving equipment, aviation and aerospace instrumentation, automatic instrumentation equipment, and devices working in oil wells and mines. The common thread is a device that is hard to reach and expensive to service.
Medical and wireless instruments — portable medical devices and wireless communication nodes — choose it where the interval between battery changes matters more than peak power.
It is the wrong choice for sustained high current. Motors, heaters and continuously transmitting radios draw far more than a bobbin-type primary lithium battery can supply, and those designs need a different chemistry with a pack sized for the load.
Specifications
| Model | ER17335 |
|---|
| Type | Li-SOCl2 battery |
| Nominal voltage | 3.6 V |
| Nominal capacity | 2200 mAh |
| Max dimensions | 17.5 × 33.5 mm (diameter × height) |
| Weight | 19 g |
| Standard discharge | Discharge to 2.0 V at 2 mA |
| Max continuous discharge current | 100 mA |
| Max pulse discharge current | 200 mA |
| Discharge cut-off voltage | 2.0 V |
| Operating temperature range | -60 °C to +85 °C |
| Storage life | 10 years or more |
| Self-discharge rate | ≤1% after one year at 25 °C |
| Structure | Bobbin type |
Storage & Shelf Life
- A decade or more in storage. The rated storage life means cells can be bought in batches and meters built ahead of demand without the power source ageing out on the shelf.
- Around 1% self-discharge a year at 25 °C. Capacity is essentially intact after a year in the warehouse, and the loss stays slow as long as storage stays cool.
- Cool, dry, original packaging. Keep cells away from heat sources, direct sun and condensation, and leave them in the tray they arrived in until they go to the line.
- First in, first out. Even with a long shelf life, oldest stock should be built first so every instrument begins its field life with a full cell.
- Never charge and never reverse. This primary lithium battery is not rechargeable; a charger, a wrong-polarity socket or a test rig that applies voltage will damage the cell and can vent it.
- Keep the terminals from bridging. Loose cells rolling around a drawer with screws or clips will short across the can; store them so the terminals stay clear of metal.
Ordering & Delivery
- Confirm the cell variant. State the model, the terminal style, and whether you need it as a standard part or as a custom lithium battery built to your terminal, tab or pack drawing.
- Confirm quantity and packing. Tell us how many cells you need and how they should be packed — tray, box or bulk — so they arrive in a form your line can use.
- Confirm the transport documents. This lithium battery moves under dangerous-goods rules, so ask which documents are issued with your shipment and check the format your forwarder accepts before the cargo is booked.
- Confirm the shipping route. Shipments are usually arranged from Shenzhen, Shanghai or Hong Kong — tell us which port or airport suits your forwarder.
- Confirm lead time and payment terms in writing before you lock a production schedule; both depend on quantity and configuration.
- Confirm warranty and after-sales cover. This model is listed with a one-year warranty; check what the terms include and how a claim would be handled.
- Ask about samples if the fit has to be proved in your own housing; your sales contact can confirm availability and turnaround.
- If the instrument also carries a rechargeable rail, a LiFePO4 battery can be quoted alongside the primary cell so both parts arrive on one schedule.
Scale & Supply Capability
Topwell Power is a lithium battery manufacturer, not a trading house. Our range runs from compact packs to large storage systems, so buyers can consolidate several lines behind one specification standard and one set of shipping documents. OEM and private-label work is routine: your label, case marking, terminal choice, capacity and packing configuration. Capacities and enclosures are customised per project, samples are available before a production run, and shipments go out with the transport documentation freight forwarders ask for. Send your target specification and volume, and we will confirm lead time, packing and pricing for that order.
Cell assembly | Enclosed, automated assembly with in-line inspection Cell grading | Cells sorted by capacity and voltage before release Final inspection | 100% check on appearance, voltage, capacity, resistance and dimensions Packing | Packed to the requirements of the chosen air or sea route Safety certificate | CE, as listed for this model Environmental certificate | RoHS, as listed for this model Quality management | ISO 9001 and ISO 14001 systems at factory level Factory audits | SGS and Intertek audits of the production system
FAQ
Is this cell rechargeable?
No. It is a lithium thionyl chloride primary cell, and there is no rechargeable version of this chemistry in this format. Applying charge damages it and can vent electrolyte, so the instrument must contain no path that feeds voltage back into the cell. Designs that need recharging should use a rechargeable lithium battery with matching charge control.
Can we replace two 1.5 V alkaline cells with one of these?
Only if the electronics are rated for 3.6 V. Two alkaline cells supply about 3.0 V, and a fresh thionyl chloride cell sits at its nominal 3.6 V or slightly above, which can exceed the maximum input of a regulator designed around a 3 V rail. Check the input rating of every device on that rail before substituting.
How much current can it supply?
The continuous rating is 100 mA and the maximum pulse is 200 mA, with the standard discharge measured at 2 mA down to 2.0 V. That covers metering electronics and short transmission bursts; it does not cover motors, heaters or continuous transmitters. If your peak load sits at or above the pulse rating, a spiral-construction cell is the better fit.
How long can cells sit in the warehouse, or in built meters, before commissioning?
The rated storage life is 10 years or more, with self-discharge around 1% a year at 25 °C, so an instrument assembled now can stand in stores and still be commissioned years later with nearly all of its capacity. Keep stock cool and dry, build oldest first, and leave cells in their original packaging until assembly.
Could a LiFePO4 battery work in the same instrument instead?
Only with charge control and a protection circuit. A LiFePO4 battery is a rechargeable chemistry that expects a charger and a BMS, and it brings a different voltage window and charge profile. The primary cell needs neither, which is why it suits sealed devices that are never recharged.
How should spent cells be handled?
Send them to a lithium battery recycling stream rather than general waste. Do not open, crush, incinerate or attempt to recharge them, and isolate any cell that has been mechanically damaged, handling it as damaged lithium cargo under your local rules.
Can you supply this cell in a pack or with leads?
Single cells are the standard form, and multi-cell lithium thionyl chloride packs are also built for instruments that need a higher voltage or a longer runtime. If your design needs a specific terminal, lead length or pack shape, describe it and it will be quoted as a custom lithium battery for your device.